Repair/Leica Flexline Standard Maintenance
-Incoming inspection
-Circle cleanliness inspection
-Cleaning of circle (if necessary)
-Cleaning and greasing of focusing system (if necessary)
-Inspecting & adjusting of laser beam paths (IR/RL EDM)
-Inspecting & adjusting of laser beam path of EGL, if applicable
-Inspecting of Autoheight (if applicable)
-Determining of vertical, length and traverse index
-Determining/adjusting of Hz collimation error
-Determining of tilting axis error
-Installation of latest firmware & applications (if
valid software maintenance contract exists)
-Check/Determining EDM additive constant
-Outgoing inspection
-Cleaning of instrument and accessories
-Calibration Certificate